Internal curtain walls
GASBETON® EVOLUTION
for load-bearing masonry
Blocks suitable for sound-insulating, fire-resistant internal partitions and for external load-bearing masonry in non-seismic zones.
This product has the longest history for use on internal partitions, for large fire-resistant masonry, or for curtain walls, even with load-bearing function in low seismic zones. GASBETON® EVOLUTION has a dry density of 480 kg/m³ and offers stationary thermal transmittance of less than 0.3 W/m²K and sound insulation values of up to 54dB, combined with high load-bearing capacity and unparalleled fire resistance. This excellent mix of different performances makes the product versatile and suitable for all needs.


up tp
U = 0,20 W/m2K
External infill panels
GASBETON® ACTIVE
for non-load-bearing masonry
This block does not require additional thermal coats and maximises thermal insulation in both winter and summer, for passive and nzeb building masonry.
It is currently the most insulating on the market (300 kg/m3) and allows the construction of curtain walls on framed structures with thermal performance similar to insulating materials, thanks to conductivity values of 0.07 W/mK, while maintaining the highest level acoustic insulation performance and thermal inertia, without the need for additional insulating materials. GASBETON® ACTIVE was created to offer a specific response to building demands, which are increasingly sensitive to the issues of eco-sustainability, energy savings and living comfort in both winter and summer months.


up tp
U = 0,14 W/m2K
External infill panels
GASBETON® ENERGY
for non-load-bearing masonry
Blocks that optimise thermal and acoustic insulation performance for single-layer curtain walls
Characterised by an excellent insulation value (350 kg/m3), it allows the construction of infill masonry on framed structures with thermal performance similar to insulating materials, thanks to conductivity values of 0.08 W/mK, while maintaining the highest level acoustic insulation performance and thermal inertia, without the need for additional insulating materials. GASBETON® ENERGY is a specific response to building demands, which are increasingly sensitive to the issues of eco-sustainability, energy savings and living comfort in both winter and summer months.


up tp
U = 0,19 W/m2K
Load-bearing masonry
GASBETON® SYSMIC
for load-bearing masonry
Blocks with a load-bearing capacity of more than 50 kg/cm2 specifically designed for load-bearing walls in seismic zones.
Characterised by a higher mixture density, 580 kg/m³, GASBETON® SYSMIC makes it possible to build ordinary load-bearing masonry even in highly seismic zones.
Measurements
Dimensions:: 60 x 25 cm (length x heigh)
Thickness:: from 24 to 37,5 cm


up tp
U = 0,33 W/m2K
Thermal break
GASBETON® IDRO
Reduces thermal bridges and ascending moisture!
The faithful friend of a healthy home with dry wall. A special version of GASBETON® mass water-repellent to cut out capillary ascending moisture from the ground and reduce thermal bridges at the base of traditional masonry.
From the functional need to reduce thermal bridges at the base of traditional masonry and, at the same time, the transmission of any ascending moisture comes the new IDRO Block. In addition to its excellent thermal insulation power and high compressive strength, this product offers much lower absorption values compared to standard blocks, thanks to the use of special waterproofing agents evenly distributed throughout the entire volume of the block.

Idro Evolution Measurement
Dimensions: 60 x 25 cm (length x height)
Thickness: from 8 to 50 cm
Idro Sysmic Measurement
Dimensions: 60 x 25 cm (length x height)
Thickness: from 24 to 40 cm
Fields of application: IDRO blocks are ideal for the construction of the first course of bricks at the base of traditional masonry and in GASBETON® in order to inhibit moisture and, at the same time, reduce linear thermal bridges. It is suitable both for internal partitions and external walls, including load-bearing in seismic zones. It is useful in basements, ground floors and in all areas where there are balconies or terraces with a danger of water stagnation.
Special pieces

EVOLUTIONGrooved Blocks
Length x Height = 60×25 cm
• cod. V520LU: thickness 20 cm
• cod. V524LU: thickness 24 cm
• cod. V530LU: thickness 30 cm
• cod. V535LU: thickness 35 cm
• cod. V537LU: thickness 37,5 cm
• cod. V540LU: thickness 40 cm
• cod. V545LU: thickness 45 cm

EVOLUTIONHollow Blocks
Length x Height = 60×25 cm
• cod. V520LO: thickness 20 cm
• cod. V524LO: thickness 24 cm
• cod. V530LO: thickness 30 cm
• cod. V545LO: thickness 45 cm

SYSMICHollow Blocks
Length x Height = 60×25 cm
• cod. VSY24LO: thickness 24 cm
• cod. VSY30LO: thickness 30 cm

Lintels
NON LOAD-BEARING THIN LINTELS h 25 cm
thickness: 7,5 cm
• cod. AS12508V: length 125 cm
thickness: 10 cm
• cod. AS12510V: length 125 cm
• cod. AS15010V: length 150 cm
• cod. AS17510V: length 175 cm
• cod. AS20010V: length 200 cm
• cod. AS25010V: length 250 cm
NON LOAD-BEARING REDUCED-HEIGHT LINTELS h 12,5 cm
thickness: 11,5 cm
• cod. AR15012V: length 150 cm
• cod. AR20012V: length 200 cm
• cod. AR25012V: length 250 cm
• cod. AR30012V: length 300 cm
thickness: 15 cm
• cod. AR15015V: length 150 cm
• cod. AR20015V: length 200 cm
• cod. AR25015V: length 250 cm
• cod. AR30015V: length 300 cm
LOAD-BEARING LINTELS h 25 cm
thickness: 20 cm
• cod. AA130200: length 130 cm
• cod. AA175200: length 175 cm
• cod. AA200200: length 200 cm
• cod. AA250200: length 250 cm
• cod. AA300200: length 300 cm
thickness: 24 cm
• cod. AA130240: length 130 cm
• cod. AA175240: length 175 cm
• cod. AA200240: length 200 cm
thickness: 30 cm
• cod. AA130300: length 130 cm
• cod. AA175300: length 175 cm
• cod. AA200300: length 200 cm

MURFOR COMPACTWire mesh tape for reinforcement joints
• cod. ACMURA40: width 4 cm
• cod. ACMURA80: width 8 cm